Separate Overlapping Links layout algorithm properties

When the Separate Overlapping Links schematic layout algorithm is chosen in the Layout Task drop-down list, clicking the Layout Algorithm Properties button Layout Algorithm Properties icon on the Schematic Editor toolbar opens its associated properties dialog box as follows:

Separate Overlapping Links properties dialog box

The parameter values are either those specified by default by Schematics or those specifically set as default for the schematic diagram template related to the active diagram using the Schematic Dataset Editor's Layout Task tab for this schematic diagram template.

Offset between links parameter

The Offset between links parameter determines the spacing that will separate two schematic links after the layout algorithm execution. This offset also determines the distance between the origin/end schematic node of the links and the first /last break point that is automatically inserted on the links (figure 3.1 below). The offset unit depends on the Absolute units check box.

Separate Overlapping Links—Offset explanation

The figures below show the Offset between links parameter while the Absolute units check box is unchecked. Figure 3.2 shows the initial schematic diagram. Figure 3.3 is obtained after the Separate Overlapping Links algorithm execution with Offset between links = 0.5. Figure 3.4 shows the result obtained with Offset between links = 2.

Separate Overlapping Links—Offset example

Use origin links check box

The Separate Overlapping Links layout algorithm operates on schematic links contained in the diagram in two different ways. Either it works on schematic links that have the same origin and extremity nodes and the exact same path and number of vertices—and where all those vertices overlap, so the links completely overlap—or it works on schematic links that have the same origin and extremity nodes but a different link path.

The Use origin links check box allows you to determine which type of links will be treated:

The figures below show the Use origin links check box. Figure 1.1 shows the initial schematic diagram with no schematic feature selected. Figure 1.2 is obtained after the Separate Overlapping Links layout algorithm execution, and the Use origin links box is unchecked—the algorithm worked on the whole diagram. It searched for the real overlapping links in the diagram and separated them according to the Offset between links parameter.

NotaNota:

If the two links separated in Figure 1.2 had been selected before the algorithm execution, these links would have been separated in the exact same way.

Scenario 1
Figures 2.1 and 2.2 show the second working way of the layout algorithm. Figure 2.1 shows the initial schematic diagram with only one selected schematic link. When the Use origin links check box is checked, the selected link is used as a reference link for the algorithm execution. The algorithm copies the vertices that display along that link on the second link, which connects the same origin and extremity nodes and separates the two links according to the Offset between links parameter value. If there were no selected schematic links when the algorithm was launched, nothing would have happened.
Scenario 2

Absolute units check box

By default, the Offset between links parameter value is interpreted as absolute units determined by the coordinate system specified on the XY Coordinate System tab of the Schematic Diagram Properties dialog box (with the Absolute units check box checked). Uncheck the Absolute units check box if you want this parameter value to be interpreted as units relative to the average of the current symbol sizes used to represent the schematic nodes in the diagram. In this case, when the Offset between links parameter value is 2, the distance that will separate two schematic feature links after the algorithm execution will correspond to the average size of two symbols placed side by side.

NotaNota:

Specifying parameters in relative units is easier than in absolute units but has a real meaning only when there is a reference scale for the diagram.

Restore Defaults button

Click the Restore Defaults button to reinitialize all the Separate Overlapping Links parameters with their default values. The restored values are either those specified by default by Schematics or those specifically set as default for the schematic diagram template related to the active diagram using the Schematic Dataset Editor's Layout Task tab for this schematic diagram template.

Temas relacionados


7/11/2012