000782 : Read only data or unversioned data cannot be checked out. Full versioning is required for all replica data.

Description

This error happens if the data you are trying to replicate has not been properly configured for replication.

Solution

Ensure the replica datasets meet the following requirements:

  • The database user must have write access to the data.
  • All data must be registered as versioned.
  • The data cannot be versioned with the option to move edits to base.
Two-way and one-way replicas have these additional requirements:
  • Each dataset must have a GlobalID column. This column is used to maintain row uniqueness across geodatabases.
  • All spatial data must be stored in a high-precision spatial reference.
For more information, see Preparing data for replication.