Creating a holding pattern procedure leg
The Procedure Leg HA, HF, HM function creates a holding pattern procedure leg feature based on a single specified coordinate and other input parameters like distance, radius, and azimuth.
- Start ArcMap.
- On the menu bar, click Customize > Toolbars > Production Feature Builder.
-
Click the Launch Feature Builder button on the Production Feature Builder toolbar.
The Feature Builder window appears in ArcMap.
Tip:The Feature Builder window can be placed anywhere in ArcMap, or in the TOC, with the aid of the arrows showing the possible placement positions.
-
Choose Procedure Leg HA, HF, HM in the list on the Functions tab.
-
Define a coordinate for the start point of the polyline by doing one of the following:
- Clicking the Pinprick button on the Production Feature Builder toolbar, then clicking on the map
- Typing the coordinates in the cells on the Input tab in the Coordinates area
Tip:To view the input coordinates on the map, double-click the row headers for each coordinate.
-
Click the cell next to Distance and type the value.
This is the distance between the specified point and the 180-degree turn. The default unit is Nautical Miles.
Tip:You can right-click the parameter name and change the unit of measurement. If you change the unit of measurement after defining a value, the value is converted to the new unit of measurement, and you may need to redefine the value.
-
Click the cell next to Radius and type a value.
This is the radius for the procedure leg holding pattern. The default unit is Nautical Miles.
Tip:You can right-click the parameter name and change the unit of measurement. If you change the unit of measurement after defining a value, the value is converted to the new unit of measurement, and you may need to redefine the value.
-
If necessary, click the drop-down arrow next to Clockwise and click False.
This indicates whether the procedure leg is created in a clockwise direction. There are two options:
- True—The arc is created in a clockwise direction, so the procedure leg extends above the input coordinate.
- False—The arc is created in a counterclockwise direction, so the procedure leg extends below the input coordinate.
-
Click the cell next to Azimuth and type a value for the angle at which the procedure leg is going to be oriented.
This is the angle for the procedure leg from the specified coordinate. The default unit is degrees.
Tip:You can right-click the parameter name and change the unit of measurement. If you change the unit of measurement after defining a value, the value is converted to the new unit of measurement, and you may need to redefine the value.
-
If necessary, click the cell next to MagVar Value and type a value for the magnetic variation.
This can be a specified value or from a field defined in the MagVar Source parameter. The default unit is degrees.
-
If necessary, click the drop-down arrow next to MagVar Source and choose a source for the magnetic variation.
This is the source of the magnetic variation value.
-
If necessary, click the drop-down arrow next to MagVar Year and choose a different year for the World Magnetic Model.
This is the year associated with the magnetic variation value.
- Click the Execute button .
You can right-click the parameter name and change the unit of measurement. If you change the unit of measurement after defining a value, the value is converted to the new unit of measurement, and you may need to redefine the value.
A polygon representing a holding pattern procedure leg is created.
If the polygon does not appear, click the Add Scratch Data Layers button at the top of the Feature Builder window.